68 ASC 110
396040
HIDE
SPN110FMI10
HIGH COOLANT TEMP
SHUTDOWN
396041
1 of x
MORE
HIDE
SPN110FMI10
HIGH COOLANT TEMP
SHUTDOWN
1 of x
MORE
396042
ENG RPM
396043
2000 RPM
ENG RPM
COOL TEMP
1100
0
2200
2.6. Actuators and dashboard instruments
ENGINE CUT OFF ALARM
Alarm signal indicated by red LED ON informs about engine’s
substantial defect – Shut o engine.
Engine failure registered from engine ECU (Electronic Actuator
Unit) will be displayed via error code for a failure and description
on the display warning to “SHUT DOWN .
Press ENTER to acknowledge and hide the display.
Return to display 1 of parameter display with “SHUT DOWN“
warning icon in RH corner.
Reduce engine power, stop the machine
immediately at safe place and shut o
the engine! Call Cummins service cen-
tre to repair the defect. Do NOT operate
the machine, unless the defect has been
repaired!