Programming
85
NXD-500i 5" Modero Wall/Flush Mount Touch Panel with Intercom
"^" Button Commands (Cont.)
^ENA Enable or disable buttons with a set variable text range.
Syntax:
"'^ENA-<vt addr range>,<command value>'"
Variable:
variable text address range = 1 - 4000.
command value = (0= disable, 1= enable)
Example:
SEND_COMMAND Panel,"'^ENA-500.504&510.515,0'"
Disables button pushes on buttons with variable text range 500-504 & 510-515.
^FON Set a font to a specific Font ID value for those buttons with a defined address range.
Note: The Font ID is generated by TPD4 and is located in TPD4 through the Main menu. Panel >
Generate Programmer's Report >Text Only Format >Readme.txt.Syntax:
"'^FON-<vt addr range>,<button states range>,<font value>'"
Variable:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
font value = Range = 1 - XXX. Refer to theDefault Font Styles and ID Numbers table on page 72.
Example:
SEND_COMMAND Panel,"'^FON-500.504&510.515,1&2,4'"
Sets the font size to font ID #4 for the On and Off states of buttons with the variable text range of
500-504 & 510-515.
^GDI Change the bargraph drag increment.
Syntax:
"'^GDI-<vt addr range>,<bargraph drag increment>'"
Variable:
variable text address range = 1 - 4000.
bargraph drag increment = The default drag increment is 256.
Example:
SEND_COMMAND Panel,"'^GDI-7,128'"
Sets the bargraph with variable text 7 to a drag increment of 128.
^GIV Invert the joystick axis to move the origin to another corner. Parameters 1,2, and 3 will cause a
bargraph or slider to be inverted regardless of orientation. Their effect will be as described for
joysticks.
Syntax:
"'^GIV-<vt addr range>,<joystick axis to invert>'"
Variable:
variable text address range = 1 - 4000.
joystick axis to invert = 0 - 3.
For a bargraph 1 = Invert , 0 = Non Invert
Example:
SEND_COMMAND Panel,"'^GIV-500,3'"
Inverts the joystick axis origin to the bottom right corner.
0
2
3
1
1 = Invert horizontal axis
2 = Invert vertical axis
3 = Invert both axis locations
0 = Normal