Setup Pages and Descriptions
50
NXD-500i 5" Modero Wall/Flush Mount Touch Panel with Intercom
Security Settings
The Security button on the Protected Setup page has three settings: Standard, Secure, and DoD. Pressing the button
opens the Panel Security Setting popup window (FIG. 49)
Each of the settings has different features for touch panel security:
For more information on configuring AMX devices for a secure environment, please refer to the guide Security Profiles:
Configuring AMX Devices For Installation Into a Secure Environment, available at www.amx.com.
FIG. 49 Panel Security Setting popup window
Security Profile Features
Standard: Factory default, shipped in this configuration.
Default Protected Setup Password is “1988”.
Remote login uses Telnet.
Secure: Default Protected Setup Password is “Amx1234!”.
Minimum password requirement is 8 characters with at least one numeric character.
Remote login uses SSH.
Remote login user name is “amx”.
Login failure attempt pauses 4 seconds before another login attempt is allowed.
After 3 consecutive unsuccessful SSH login attempts, login lockout is enabled for 15 minutes.
Login and logout audit logging is enabled.
DoD: Default Protected Setup Password is “Amx1234!”.
Minimum password requirement is 8 characters with at least one numeric character, one uppercase
character, one lower case character, and one special character, with no duplicate adjacent characters.
Remote login uses SSH.
Remote login user name is “amx”.
Login failure attempt pauses 4 seconds before another login attempt is allowed.
After 3 consecutive unsuccessful SSH login attempts, login lockout is enabled for 15 minutes.
Login and logout audit logging is enabled.
DoD login banner is enabled.
A transition from one security mode to another will reset the Protected/Web Control/
remote login password to the default value for the current security mode (please refer
to the default passwords above). A transition to Secure or DoD mode will disable G4
Web Control. Although the security password features are immediate, a reboot must
occur for all the new security mode features to fully take effect.