DualWave Arthroscopy Pump User’s Guide
DFU-0212 Rev. 1 Page 18 of 54
2
2
.
.
5
5
.
.
3
3
ReDeuce™ Pump Tubing Set (AR-6411: Region A)
The ReDeuce Pump Tubing Set is intended to be used in conjunction with
the ReDeuce Patient Tubing Set (AR-6421) to offer inflow and pressure
sensing tubing. It is not intended to be used as a stand-alone product. The
ReDeuce Pump Tubing Set may be used for an entire surgical day, unless
sterility is compromised in any way. From the pump, the tubing is 0.5
meters (1.7 ft.) in length.
2
2
.
.
5
5
.
.
4
4
ReDeuce Patient Tubing Set (AR-6421: Region A)
The ReDeuce Patient Tubing Set is intended to be used in conjunction with
the ReDeuce Pump Tubing Set to allow the use of the ReDeuce Pump Tubing
Set for an entire surgical day, while replacing only the ReDeuce Patient
Tubing Set after each individual surgery. The backflow check valve built
into the ReDeuce Patient Tubing Set prevents contaminated fluid from
back-flowing into the ReDeuce Pump Tubing Set, maintaining a closed
sterile fluid environment during tubing replacements. The patient tubing
is 2.4 meters (8 ft.) in length.
2
2
.
.
5
5
.
.
5
5
Extension Tubing System (AR-6220: Region A)
The Extension Tubing System is intended to be used in conjunction with
the Main Pump Tubing Set (AR-6410) to allow the Main Pump Tubing Set to
be used for an entire surgical day, while only replacing the Extension
Tubing System after each individual surgery. The extension tubing is 2.4
meters (8 ft.) in length.
2
2
.
.
5
5
.
.
6
6
One-Piece Tubing Set System (AR-6415/AR-6415CL: Region B)
The One-Piece Tubing System offers inflow and pressure sensing tubing.
The One-Piece Tubing System is intended to be used for ONLY one
procedure and must be replaced after each patient.
The only difference between the AR-6415 and the AR-6415CL model is
that the bag spikes on the “CL” model are CareLock spikes which are
used specifically with Fresenius fluid bags.
2
2
.
.
5
5
.
.
7
7
Main Pump Tubing Set (AR-6420/AR-6420CL: Region B)
The Main Pump Tubing Set is intended to be used in conjunction with the
Patient Extension Tubing System (AR-6425) to offer inflow and pressure
sensing tubing. It is not intended to be used as a stand-alone product. The
Main Pump Tubing Set may be used for an entire surgical day, unless
sterility is compromised in any way.
The only difference between the AR-6420 and the AR-6420CL model is
that the bag spikes on the “CL” model are CareLock spikes which are
used specifically with Fresenius fluid bags.