122 G12 OEM Board & Sensor Reference Manual
ELM: Elevation Mask for Raw Measurements Outputs
$PASHS,ELM,d1
This command allows you to set the minimum elevation for the output of raw
measurement data (CT1, MBN, MCA, etc.), where d1 is a number between 0 and
90. The receiver can be set to output raw measurement data for each satellite it is
tracking that is above the elevation mask. It stops outputting raw measurement data
for any satellite at or below the elevation mask. If the elevation mask is set to 10°,
the receiver outputs raw measurement data for all tracked satellites with an
elevation of 11° or higher, but not output raw measurement data for any tracked
satellites with an elevation of 10° or lower. You can view the current raw data
elevation mask setting $PASHQ,RAW and checking the ELM field.
Examples
Enter the following command to set the elevation mask at ten degrees:
$PASHS,ELM,10
Enter the following command to set the elevation mask at fifteen degrees:
$PASHS,ELM,15
DEFAULT SETTING
ELM