CHAPTER 6 EXPANDED EMERGENCY AND ABNORMAL PROCEDURES
Page 6-8
091-00027-001 REV A Evolution Backup Display Pilots Guide
Page 6-9
091-00027-001 REV A
Evolution Backup Display Pilot’s Guide
6.4. Abnormal Shutdown Procedure
The EBD is typically powered through an EBD master switch that is connected to the
aircraft’s Battery bus. Normally, the EBD will power down when the EBD Master switch
is turned OFF or when aircraft power is removed when on the ground. To force the EBD
to power down, the following procedures are provided.
Shutdown EBD (on ground)
1. EBD Master switch OFF
2. Press and hold the PWR Button until the display turns o (Figure 6-1)
Or
1. Press the MENU Button.
2. Rotate the Top Knob to the POWER SETTINGS Menu page
3. Press the SHUT DOWN Menu Key. The power down sequence initiates, and a
power down message displays
A powering o annunciation displays indicating that the unit will shut down in 5
seconds. The pilot can press any control to abort the power-down sequence.
Power On Manually
• Press and hold the PWR Button until the EBD powers on.
Figure 6-1
Powering O the
EBD
091-00027-001 Rev A EBD Pilots Guide V&H .indb 8 8/27/14 8:51 AM