EasyManua.ls Logo

Atlas Copco FOCUS 60 - Page 62

Atlas Copco FOCUS 60
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Programming Focus 60 / Focus 61 Focus 60 / Focus 61 User Guide
62 (106) 9839 0211 01 Edition 1.1
FUNCTION
DESCRIPTION
Rehit Value (°)
If the torque reaches the click value within this angle, it means that the screw
was already tightened.
In this case the result is marked as RNOK or ROK .
NOTE: Refer to the paragraph “Executing Tightening Operations” for
further details about the results status.
Timeout (s)
Maximum time (in seconds) of the
measurement (starting from the
moment that the torque reaches
the Cycle Start value).
The tightening operation should
be completed before the timeout
(see the figure on the right):
If the timeout is too short (or the
tightening too long) the result
might not be taken at the proper
maximum point:
Dead Time (s)
Minimum time (in seconds) among two tightening operations. This timer starts
when the torque goes below
the Cycle Start value.
Start the new tightening
operation after the Dead
Time expires:
If the operator starts a new
tightening before the Dead
Time expires, the maximum
torque value of the whole
trace is analyzed (see the
figure on the right):
Time
Timeout
Torque
Cycle start
Torque
Time
Timeout
Cycle start
Time
Torque
Dead Time
Timeout
Result 1
Result 2
Time
Result 1
Dead Time
Cycle start
Timeout
Torque

Table of Contents