TORQUE LIMITS
FUNCTION
DESCRIPTION
Cycle Start
Torque value from which the measurement of the tightening starts
Minimum torque and
Maximum torque
Torque limits to get a positive result
Change screw at
Torque limit for which the screw could be damaged by the excessive torque applied.
If the operator applies torque over this value, the result is marked as OVSC =
Additional torque limit overload screw exceeded”
Loosening limit
If the operator applies torque in the wrong direction and reach this value, the
result is marked as NEG = False direction of tightening (loosen)”.
NOTE: If the Loosening limit is set to zero, no results are detected (the
function is disabled).
ANGLE LIMITS
FUNCTION
DESCRIPTION
Minimum angle and
Maximum angle
Angle limits to get a positive result (if angle value is considered in the test
strategy).
Start final angle
Torque threshold from which the angle measurement starts.
OTHER SETTINGS
FUNCTION
DESCRIPTION
Tool size (mm)
Specific length (in millimeters) that
characterizes the end fitting tool
installed on the MWR-TA (see the
examples on the right):
NOTE: It is mandatory to enter the proper value. This value is used to
calculate the proper torque applied to the joint.
Tool Bend (° / Nm)
Bending of the end fitting tool installed on the MWR-TA.
NOTE: It is mandatory to enter the proper value. This value is used to
compensate the bending of the end fitting tool in the angle
measurement.