Focus 60 / Focus 61 User Guide Programming Focus 60 / Focus 61
9839 0211 01 Edition 1.1 61 (106)
Torque value from which the measurement of the tightening starts
Minimum torque and
Maximum torque
Torque limits to get a positive result
Torque limit for which the screw could be damaged by the excessive torque applied.
If the operator applies torque over this value, the result is marked as “OVSC =
Additional torque limit “overload screw” exceeded”
If the operator applies torque in the wrong direction and reach this value, the
result is marked as “NEG = False direction of tightening (loosen)”.
NOTE: If the Loosening limit is set to zero, no results are detected (the
function is disabled).
Minimum angle and
Maximum angle
Angle limits to get a positive result (if angle value is considered in the test
strategy).
Torque threshold from which the angle measurement starts.
Specific length (in millimeters) that
characterizes the end fitting tool
installed on the MWR-TA (see the
examples on the right):
NOTE: It is mandatory to enter the proper value. This value is used to
calculate the proper torque applied to the joint.
Bending of the end fitting tool installed on the MWR-TA.
NOTE: It is mandatory to enter the proper value. This value is used to
compensate the bending of the end fitting tool in the angle
measurement.