47
Zone (KP) Video Out
1. Using RG6 quad shield coaxial cable terminated with male F
connectors, connect the appropriate
KP Video Output 1–6
Terminal
on the AVH21, as shown in Figure 28, to the
appropriate Zone 1–6 video display composite video input.
NOTE: The AVH21 only has video outputs for Zones 1–6.
Confirm proper connection by zone (keypad number).
Improper connection will cause operational errors such as
misrouted video signals.
2. In larger systems using multiple hubs, repeat Step 1 for all
KP
Video Output
connections to AVH21 #s 1, 2 and 3 for all
zones configured for video. Confirm all connections by zone
(keypad number), as shown in
Figure 28.
a) AVH21 #1 connects to video displays in Zones 1–6
b) AVH21 #2 connects to video displays in Zones 8–13
c) AVH21 #3 connects to video displays in Zones 15–20
NOTE: Each AVH21 only has six zone video outputs. It is
recommended that audio-only zones such as common areas
like hallways and patios be connected to Zones 7 and 14.
Hub System
AVH21 #1
ZONES 1–7
AVH21 #2
ZONES 8–14
AVH21 #3
ZONES 15–20
STRUCTURED WIRING PANEL
COMPOSITE VIDEO
FROM AVH21 #2
KP 8–13 VIDEO OUTPUTS
TO ZONE 8–13 VIDEO DISPLAYS
COMPOSITE VIDEO
FROM AVH21 #3
KP 15–20 VIDEO OUTPUTS
TO ZONE 15–20 VIDEO DISPLAYS
COMPOSITE VIDEO
FROM AVH21 #1
KP 1–6 VIDEO OUTPUTS
TO ZONE 1–6 VIDEO DISPLAYS
TO ZONE VIDEO DISPLAY