User's Manual 64. Technical Specifications
64 Technical Specifications
The device's technical specifications are listed in the table below.
Note:
• All specifications in this document are subject to change without prior notice.
• The compliance and regulatory information can be downloaded from AudioCodes
Web site at http://www.audiocodes.com/library.
Table 64-1: Technical Specifications
Function Specification
Interfaces
PSTN Modularity and
Capacity
6 Slots for hosting voice processing and PSTN termination modules
(up to 192 channels)
Digital Module
Up to 6 E1/8 T1/J1 spans, provided on the TRUNKS module. Each
module supports 1, 2, or 4 E1/T1/J1 spans (RJ-48c ports), with an
option of PSTN Fallback.
BRI Module
Up to 20 BRI ports, provided on the BRI modules, where each
module supports up to 4 BRI ports, with an option of PSTN Fallback.
The BRI provides network S/T interfaces; NT or TE termination; 2W
per port (power supplied).
The maximum cable length for a point-to-point BRI service (BRI port
to BRI endpoint) is 1,000 m (3,280 ft).
Analog Module
Up to 24 FXS/FXO interfaces, provided on 4-ports FXS/FXO
modules, where each module supports up to 4 ports (RJ-11).
Support ground- and loop-start signaling.
Note: The device is an indoor unit and thus, the device and these
interfaces must be installed only indoors.
Media Processing Module
Up to 4 Media Processing modules (MPM), providing additional DSP
resources
Networking Interfaces
Ethernet
Up to 6 GE interfaces, configured in 1+1 redundancy or as individual
ports.
Security
Access Control
DoS/DDoS line rate protection, bandwidth throttling, dynamic
blacklisting
VoIP Firewall
RTP pinhole management, rogue RTP detection and prevention, SIP
message policy, advanced RTP latching
Encryption and
Authentication
TLS, DTLS, SRTP, HTTPS, SSH, client/server SIP Digest
authentication, RADIUS Digest
Privacy
Topology hiding, user privacy
Traffic Separation
VLAN/physical interface separation for multiple media, control and
OAMP interfaces

Table of Contents

Other manuals for AudioCodes Mediant 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 1000 and is the answer not in the manual?

AudioCodes Mediant 1000 Specifications

General IconGeneral
Data link protocolsCAS: MF-R1: T1 CAS, ISDN PRI: ETSI/EURO ISDN, ANSI NI2, QSIG
Security algorithmsHTTPS, SRTP
Authentication methodRADIUS
Internal memory512 MB
Built-in processorCeleron 600 MHz
Processor frequency600 MHz
Internal memory type-
Number of processors installed1
Voice codecsG.711, G.723.1, G.726, G.729A, iLBC
SafetyUL60950-1, FCC 47 CFR
CertificationETS 300019-2-1, ETS 300019-2-2 ETS 300019-2-3
Mounting typeRack mounting
LED indicatorsYes
Power requirements90-260 V AC
Weight and Dimensions IconWeight and Dimensions
Size (imperial)19 \