User's Manual 56. Self-Testing
56 Self-Testing
The device features the following self-testing modes to identify faulty hardware
components:
Detailed Test (Configurable): This test verifies the correct functioning of the different
hardware components on the device. This test is done when the device is taken out of
service (i.e., not in regular service for processing calls). The test is performed on
startup when initialization of the device completes.
To enable this test, set the ini file parameter, EnableDiagnostics to 1 or 2, and then
reset the device. Upon completion of the test and if the test fails, the device sends
information on the test results of each hardware component to the Syslog server.
The following hardware components are tested:
DSPs - when EnableDiagnostics = 1 or 2
Analog interfaces - when EnableDiagnostics = 1 or 2
Note:
To return the device to regular operation and service, disable the test by setting
the ini file parameter, EnableDiagnostics to 0, and then reset the device.
While the test is enabled, ignore errors sent to the Syslog server.
Startup Test (automatic): This hardware test has minor impact in real-time. While
this test is executed, the regular operation of the device is disabled. If an error is
detected, an error message is sent to the Syslog.

Table of Contents

Other manuals for AudioCodes Mediant 1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 1000 and is the answer not in the manual?

AudioCodes Mediant 1000 Specifications

General IconGeneral
Data link protocolsCAS: MF-R1: T1 CAS, ISDN PRI: ETSI/EURO ISDN, ANSI NI2, QSIG
Security algorithmsHTTPS, SRTP
Authentication methodRADIUS
Internal memory512 MB
Built-in processorCeleron 600 MHz
Processor frequency600 MHz
Internal memory type-
Number of processors installed1
Voice codecsG.711, G.723.1, G.726, G.729A, iLBC
SafetyUL60950-1, FCC 47 CFR
CertificationETS 300019-2-1, ETS 300019-2-2 ETS 300019-2-3
Mounting typeRack mounting
LED indicatorsYes
Power requirements90-260 V AC
Weight and Dimensions IconWeight and Dimensions
Size (imperial)19 \