CHAPTER19 Coders and Profiles
Mediant 4000 SBC | User's Manual
Parameter Description
'Fax Mode'
sbc-fax-behavior
[IpProfile_SBCFaxBehavior]
Enables the device to handle fax offer-answer negotiations
for the SIP entity associated with the IP Profile.
[0] As Is = (Default) Device forwards fax transparently,
without interference.
[1] Handle always = Handle fax according to fax
settings in the IP Profile for all offer-answer
transactions (including the initial INVITE).
[2] Handle on re-INVITE = Handle fax according to fax
settings in the IP Profile for all re-INVITE offer-answer
transactions (except for initial INVITE).
Note: The fax settings in the IP Profile include IpProfile_
SBCFaxCodersGroupName, IpProfile_
SBCFaxOfferMode, and IpProfile_SBCFaxAnswerMode.
'Fax Offer Mode'
sbc-fax-offer-mode
[IpProfile_SBCFaxOfferMode]
Defines the coders included in the outgoing SDP offer (sent
to the called "fax") for the SIP entity associated with the IP
Profile.
[0] All coders = (Default) Use only (and all) the coders
of the selected Coder Group configured using the
SBCFaxCodersGroupID parameter.
[1] Single coder = Use only one coder. If a coder in the
incoming offer (from the calling "fax") matches a coder
in the SBCFaxCodersGroupID, the device uses this
coder. If no match exists, the device uses the first
coder listed in the Coders Group ID
(SBCFaxCodersGroupID).
Note: The parameter is applicable only if you set the
IpProfile_SBCFaxBehavior parameter to a value other than
[0].
'Fax Answer Mode'
sbc-fax-answer-mode
[IpProfile_
SBCFaxAnswerMode]
Defines the coders included in the outgoing SDP answer
(sent to the calling "fax") for the SIP entity associated with
the IP Profile.
[0] All coders = Use matched coders between the
incoming offer coders (from the calling "fax") and the
coders of the selected Coder Group (configured using
the SBCFaxCodersGroupID parameter).
[1] Single coder = (Default) Use only one coder. If the
incoming answer (from the called "fax") includes a
coder that matches a coder match between the
incoming offer coders (from the calling "fax") and the
coders of the selected Coder Group
(SBCFaxCodersGroupID, then the device uses this
coder. If no match exists, the device uses the first
listed coder of the matched coders between the
incoming offer coders (from the calling "fax") and the
coders of the selected Coder Group.
Note: The parameter is applicable only if you set the
IpProfile_SBCFaxBehavior parameter to a value other than
[0].