EasyManuals Logo

AudioCodes Mediant 4000 SBC User Manual

AudioCodes Mediant 4000 SBC
1037 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #522 background imageLoading...
Page #522 background image
CHAPTER21 SIP Message Manipulation
Mediant 4000 SBC | User's Manual
For a detailed description of supported regex syntax, refer to the Syntax for SIP
Message Manipulation Reference Guide
Pre-Parsing Manipulation is configured using two tables with "parent-child" relationship:
â–  Pre-Parsing Manipulation Sets table ("parent"): Defines a descriptive name for the Pre-Parsing
Manipulation Set.
â–  Pre-Parsing Manipulation Rules table ("child"): Defines the actual manipulation rule. You can
configure up to 10 rules per Pre-Parsing Manipulation Set.
The following procedure describes how to configure Pre-Parsing Manipulation Sets through the
Web interface. You can also configure it through other management platforms:
â–  Pre-Parsing Manipulation Sets table: ini file [PreParsingManipulationSets] or CLI
(configure voip > message pre-parsing-manip-sets)
â–  Pre-Parsing Manipulation Rules table: ini file [PreParsingManipulationRules] or CLI
(configure voip > message pre-parsing-manip-rules)
➢ To configure Pre-Parsing Manipulation Sets:
1. Open the Pre-Parsing Manipulation Sets table (Setup menu > Signaling & Media tab >
Message Manipulation folder > Pre-Parsing Manipulation Sets).
2. Click New; the following dialog box appears:
3. Configure a Pre-Parsing Manipulation Set name according to the parameters described in the
table below.
4. Click Apply.
Table 21-4: Pre-Parsing Manipulation Set Table Parameter Descriptions
Parameter Description
'Index'
[PreParsingManipulationSets_
Index]
Defines an index number for the new table row.
Note: Each row must be configured with a unique index.
'Name'
name
[PreParsingManipulationSets_
Name]
Defines a descriptive name, which is used when
associating the row in other tables.
The valid value is a string of up to 40 characters.
Note:
â–  Each row must be configured with a unique name.
â–  The parameter value cannot contain a forward slash (/).
- 489 -

Table of Contents

Other manuals for AudioCodes Mediant 4000 SBC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 4000 SBC and is the answer not in the manual?

AudioCodes Mediant 4000 SBC Specifications

General IconGeneral
BrandAudioCodes
ModelMediant 4000 SBC
CategoryController
LanguageEnglish

Related product manuals