75
Parameter
MaxiCharger
DC Output
Power on
One EV
Charging
Cable (kW)
DC Output
Power Two EV
Charging Cables
(kW)
S
imultan
-eous
DC on
Two
Outlets
Maximum DC
Output Current
220 Max.220 kW
Max. 120 kW +
100 kW
CCS boost:
300 A (peak
400 A)
CHAdeMO
connector:
125 A/200 A
240
Max.240 kW
Max.120 kW x 2
NOTE
The actual output power varies in accordance with the voltage rating and maximum
current of the selected cable.
Power Consumption Specifications
Table 9-16 Power Consumption during Stand-by
Parameter Specification
Stand-by Power (Heater Off)
0.08 kVA
Stand-by Power (Heater On)
1.00 kVA
NOTE
The heater will operate daily when the outside air reaches the dew point, to avoid
condensation inside the cabinet. When the heater operates, the heater will use most of
the required standby power.