2. Specications
16
© Copyright Reserved Autonics Co., Ltd.
-|Transparent setting guide|-
Communication specications
Protocol Modbus RTU
Connection type RS485
Application standard Compliance with EIA RS485
Max. connection 32 units (address: 01 to 64)
Synchronization method Asynchronous
Communication method 2-wire half duplex
Communication distance Max. 800m
Communication speed 4800, 9600, 19200, 38400bps
Communication response wait time 5 to 99ms
Data bit 8-bit (xed)
Parity bit Even (xed)
Stop bit 1-bit (xed)