Items for Upgrading New file name for target
MM710B E1/T1 media module
MM711 Analog Port/Trunk media module
MM712 DCP media module
MM714 Analog Port/Trunk media module
MM714B Analog Port/Trunk media module
MM716 Analog Port/Trunk media module
MM717 24-port DCP media module
MM720 BRI media module
MM721 BRI media module
MM722 BRI Trunk media module
Related links
Installation worksheets on page 90
TFTP Server worksheet
Table 9: Global Settings for TFTP Server
TFTP Server IP Address TFTP Server Directory
Related links
Installation worksheets on page 90
TFTP server setup
To load single firmware files on an Branch Gateway, you must put the files on a computer
connected to the customer’s LAN or on an S8300 Server in the customer’s network. You log on to
the Branch Gateway later and use the gateway's TFTP capability to download the new firmware. If
you can use an S8300 Server to stage the firmware, see Installing firmware from the TFTP server
on the S8300 Server on page 93. If not, you must set up a TFTP server on the LAN.
Note:
Use a Linux or Unix TFTP server only if a Linux or Unix TFTP server already exists on the local
network. In this case, download the appropriate files to your laptop and give it to the customer
for proper placement and execution.
Related links
Upgrading firmware using the CLI through FTP/TFTP on page 88
Downloading Branch Gateway firmware files to a local TFTP server
Procedure
1. Access the
www.avaya.com/support website.
Branch Gateway firmware upgrades
February 2017 Installation and Upgrades for the Avaya Branch Gateway G430 91
Comments on this document? infodev@avaya.com