Diagnostics & Errors 8-9
Error Description
Code
371 RFID stop to encode mode must be 0 (disabled) or 1 (enabled). See “Defining the RFID
Setup Packet” for more information.
372 RFID singulate mode must be 0 (disabled) or 1 (enabled). See “Defining the RFID Setup
Packet” for more information.
373 RFID start encode position must be between 10 and 2000. See “Defining the RFID Setup
Packet” for more information.
374 RFID encode zone must be between 50 and 2000. See “Defining the RFID Setup Packet”
for more information.
375 RFID tag saver mode must be 0 (disabled) or 1 (enabled). See “Defining the RFID Setup
Packet” for more information.
376 RFID tag verify must be 0 (none), 1 (internal), 2 (external), or 3 (both). See “Defining the
RFID Setup Packet” for more information.
377 RFID verify position be between 10 and 2000. See “Defining the RFID Setup Packet” for
more information.
378 RFID TID position must be between 0 to 2000. See “Defining the RFID Setup Packet” for
more information.
379 Verify power must be -15 to 23. See “Defining the RFID Setup Packet” for more
information.
380 Job request is outside the range 0 to 4.
400 The character immediately following { is invalid.
401 Internal software failure. Call Technical Support.
402 Field separator is not in the expected location.
403 Field separator was not found.
404 The number (greater than five digits/732,000), string (greater than 2710), or tilde
sequence (greater than 255) currently being processed is out of range.
405 Too many fields exist in the format. 1000 fields is the maximum amount per format.
Lines, boxes, and constant text fields count as fields.
406 Parser error. Format or graphic is already in use. Make sure the packet is not missing |
or {} characters.
407 Parser timed out. Turn off the printer and resend the packets. If that does not solve the
problem, call Technical Support.
408 No Data. Resend packet to printer.