EasyManua.ls Logo

Avery Dennison ADTP1 - Using Option 7 Print Time;Date; Using Option 20 (Define Data Entry Prompts)

Avery Dennison ADTP1
224 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Defining Field Options 4-7
Using Option 7 Print Time/Date
The printer must contain the optional real time clock. Use this option to print the printer’s current
time and date in a format. To set the printer’s current time and date, see
Defining the Time/Date
Packet in Chapter 2.
Use with text, constant text or bar code fields.
Note: To use Option 7 with a bar code field, the bar code must support the full ASCII set of
characters.
Syntax R,7,param,format |
R1. R Option Header.
R2. 7 Option 7.
R3. param Parameter to print. Use 1 for real time clock.
R4. format Time and Date formats. 1 is the default. Options:
1 Date as 06/09/2014
2 Date and time as 06/09/2014 18:15
3 Date and time as 06/09/2014
4 Time as 18:15
5 Time as 18:15:05
Example R,7,1,2 |
Prints the date and time in the format as 06/09/2014 18:15.
Using Option 20 (Define Data Entry Prompts)
This option defines the operator prompt and it is not recommended on fields filled entirely by
fixed characters or copied data. This option must be defined before Option 5, or the prompt does
not display during data entry. Use the Monarch® 939i keyboard for offline data entry.
Syntax R,20,"prompt" |
R1. R Option Header.
R2. 20 Option 20.
R3. “prompt Displays the exact phrase to prompt the operator. Must be
enclosed within quotations. The prompt must be 15 characters or
less.
Example R,20,"Order Number" |
Displays the prompt Order Number for the operator when this field is imaged.

Table of Contents

Other manuals for Avery Dennison ADTP1

Related product manuals