8-16 Packet Reference Manual
Error Description
Code
793 The printer job queue is full. Turn off the printer. Wait 15 seconds and turn it back on.
Resend the packets. If the problem continues, call Technical Support.
794 The backfeed mode is not set.
795 Print engine lock-up. Call Technical Support.
796 No job quantity for the job setup. If this error message appears, call Technical Support.
797 No sub-job quantity for the job setup. If this error message appears, call Technical
Support.
799 Job quantity mismatch. If this error message appears, call Technical Support.
Flash Memory Errors
Error Description
Code
800 A directory in flash memory is full.
801 Flash memory is full.
802 A directory in flash memory can't be found.
803 There is no directory in flash memory.
810 A file in flash memory is not open.
811 A file in flash memory is already open.
812 The file in flash memory is full.
813 Flash memory is not accessible.
820 An error occurred in the flash program.
821 An error occurred while erasing flash memory.
822 Flash ID error.
Script Errors
These errors occur when there is a script (application) problem.
Error Description
Code
850 Invalid script packet or not enough flash memory for the script. The script download
failed. Format flash memory and download the script using the Command prompt.
851 Invalid lookup table or not enough flash memory for the script. The lookup table
download failed. Check the data in the lookup table. Format flash memory and
download the script using the Command prompt.
852 Invalid buffer definition packet or not enough flash memory for the script. Invalid input
buffer, temporary buffer, lookup buffer, printer, or array buffer. Check the buffer
definitions. Format flash memory and download the script using the Command prompt.
853 Invalid version string or not enough flash memory for the script. The version information
in the APPVERSION command is missing or invalid. Make sure the information is
enclosed in double quotation marks. Format flash memory and download the script using
the Command prompt.
854 Invalid table (string and numeric) data or not enough flash memory for the script. Check
the data. Format flash memory and download the script using the Command prompt.
855 Invalid start/clear command. The script is missing the start or clear command {S space}.

Table of Contents