4-12 Packet Reference Manual
Using Option 53 (Optional Settings for Aztec)
Use Option 53 to set the error control level, enable ECI data, enable a menu symbol, and add
appended data to an Aztec bar code. Typically, these settings are not used. When using Option
53, the printer may take longer to image the bar code and require more time to print the format.
Syntax R,53,error_ctrl,ECI,menu_sym,str_append,"string" |
R1. R Option Header.
R2. 53 Option 53.
R3. error_ctrl Error control level. Some damaged bar codes may still be
scannable if the error control level is high enough. 0 is the
default. Options:
0 Default level
1-99
101-104
201-232
300
R4. ECI Sets the ECI Data flag. 0 is the default. Options:
0 Disable
1 Enable
R5. menu_sym Sets the Menu Symbol flag. 0 is the default. Options:
0 Disable
1 Enable
R6. str_append Structured append information. Range: 1 to 26. 1 is the default.
R7. “string” String to append. Range: 0 to 24. “” is the default. Must be
enclosed in quotation marks.
Example R,53,0,0,0,1,"" |
Uses option 53 to set the error control to 0, disables the ECI data and menu symbol flags, and
does not append any data to the bar code.