8-8 Packet Reference Manual
Error Description
Code
293 The skip index selection defined in the field must be 0 (disabled) or 1 (enabled). Correct
the packet and resend to the printer.
294 The bar code verifier mode must be 0 (disable) or 1 (enable).
295 The bar code verifier’s cable detect mode must be 0 (no detect), 1 (I/O cable detect), or
2 (I/O and data cable detect).
298 Read power must be -15 to 23. See “Defining the RFID Setup Packet” for more
information.
299 Write power must be -15 to 23. See "Defining the RFID Setup Packet" for more
information.
301 Image rotation must be 0 (no rotation) or 1 (180° rotation).
302 The hours in the time/date packet must be 0 to 23.
303 The minutes in the time/date packet must be 0 to 59.
304 The day in the time/date packet must be 1 to 31.
305 The month in the time/date packet must be 1 to 12.
306 The year in the time/date packet must be 0 to 99.
Check Digit Errors
Error Description
Code
310 Check digit scheme number must be 1 to 10.
311 Modulus must be 2 to11.
312 Multi Tag Check must be 0 (Check the first tag) or 1 (Check each tag). See “Defining the
RFID Setup Packet” for more information.
313 Inlay Position is invalid. Use 0.
314 Check digit algorithm must be D (sum of digits) or P (sum of products).
Graphic Errors
Error Description
Code
325 Duplicating direction must be 0 (insert after) or 1 (insert before) in duplicate fields for
graphics.
327 Amount of row adjustment must be 0 to 999 dots in duplicate fields for graphics.
328 Duplicate count must be 0 to 999.
340 Bitmap line encoding must be H (hex) or R (run length).
350 Font selector must be 1 to 9999.
351 Font data length must be 68 to 16384.
352 Insufficient font memory is available for the downloaded font.
360 Prompt name is invalid.
362 Prompt number is invalid.
363 Prompt string is invalid.
370 RFID encode position must be between 0 and 2000. See “Defining the RFID Setup
Packet” for more information.