8-6 Packet Reference Manual
Error Description
Code
211 Narrow element value is less than 1 or greater than 99. Correct the value and resend
the format to the printer.
212 Wide element value is less than 1 or greater than 99. Correct the value and resend the
format to the printer.
213 Dimension must be 1 to 30 for a column or 3 to 90 for a row on a PDF417 bar code.
214 Truncation code must be S (standard) or T (truncated bar code).
215 Aspect code must be C (columns) or R (rows).
216 Option definition must be S (set) or T (template).
217 Input device must be D (Default), H (Host), K (Keyboard), N (None), or S (Scanner).
218 Pad direction must be L (from left) or R (from right).
219 Pad character is outside the range 0 to 255.
220 Check digit selection must be G to generate check digit.
221 Primary or secondary price format is outside the range 1 to 16.
222 Data type restriction is outside the range of 1 to 6.
223 Option is not valid for the field.
224 Bar code intercharacter gap must be 0 to 99 dots. (This is also known as the additional
character gap when using Option 50, Defining Bar Code Densities.)
226 Rule (option) Record Line xx. The upload device must be H (host) for Option 6.
231 Error control level must be 0, 1-99, 101-104, 201-232, or 300 for Option 53, Optional
Settings for Aztec bar code.
232 Invalid ECI data flag for Option 53, Optional Settings for Aztec bar code.
233 Invalid menu symbol flag for Option 53, Optional Settings for Aztec bar code.
234 Invalid structured append information for Option 53, Optional Settings for Aztec bar
code.
235 Invalid string to append for Option 53, Optional Settings for Aztec bar code.
Online Configuration Errors
Error Description
Code
251 Power up mode must be 0 (online) or 1 (offline).
252 Language selection must be 0 (English), 1 (Français), 2 (Deutsch), 3 (Español-ES), 4 (日
本語), 5 (Português), 6 (Italiano), 7 (Svenska), 8 (Español-MX), 9 (Dansk), 10
(Nederlands), 13 (Polski), 14 (Türkçe), 15 (简体中文), or 16 (Français-CA).
253 Batch separator code in a system setup packet must be 0 (off), 1 (on) or 2 (double).
254 Slash zero selection must be 0 (standard zero) or 1 (slashed zero).
255 Supply type must be 0 (black mark), 1 (die cut), 2 (continuous), or 3 (aperture)
256 Ribbon selection must be 0 (direct), 1 (transfer), or 2 (high energy).
257 Feed mode must be 0 (continuous) or 1 (on-demand).
258 Supply position must be -300 to 300 dots.
259 Contrast adjustment must be -699 to 699 dots.