Configuring the Printer 2-31
Y14. verify_power The amount of power to read an RFID inlay. The range is
-15 to 23 and the default is -15. Use the RFID Printer Setup
Utility to determine this value.
Example {I,Y,0,1,18,12,1,0,120,220,0,1,0,1,12 | }
Uses the default non-stop encode mode, enables singulate mode (1), sets the write power to 18,
the read power to 12, enables tag saver (1), does not set a TID position (0), sets the start encode
position to 120, sets the encode zone to 220, does not set an encode position (0), uses the
internal reader (1) to verify the RFID data, does not set a tag verify position (0), enables retry
encode (1), and sets the verify power to 12.