IFD500 Series Pilot Guide
General 7-19
Attempting to re-establish CrossSync
Dual IFDs have been installed and configured to share data
between the units, but there is no communication between
the IFDs. If both units are powered on, contact the Avidyne
Service Center or a local dealer for service.
One or more datalink weather products were expected but
not received within the timeout period. The Datalink Status
Page will show those that are overdue.
The tables in the “Datalink Weather Overlays And
Operations” section on page 4-18 show the products and
their associated “late” timeout periods.
Broadcast datalink receiver failure
The IFD has lost communication with the datalink receiver
or the receiver is reporting a fault. Datalink weather will be
unavailable. If the condition persists, contact a local dealer
for service.
<p> Age is greater than <x> minutes
The datalink product <p> has been received at least once
but has not been updated for <x> minutes and is now
considered stale.
The tables in the “Datalink Weather Overlays And
Operations” section on page 4-18 show the products and
their associated “stale” timeout periods.