50 Measurements
BALTECH VP-3470
Operation manual
Table 7. Parameters
Parameter
Channels
1, 2, 1+2
1, 2, 1+2
1, 2, 1+2
1, 2
1, 2
1, 2, 1+2
Type
1) velocity
2) displacement
3) acceleration
1) velocity
2) displacement
3) acceleration
1) velocity
2) displacement
3) acceleration
acceleration
acceleration
1) velocity
2) displacement
3) acceleration
Units
1) mm/s, dB
2) um, dB
3) m/s2, 
dB, g
1) mm/s
2) um,
3) m/s2, g
1) mm/s, dB
2) um, dB
3) m/s2, 
dB, g
m/s2, g
m/s2, g
11) mm/s, dB
2) um, dB
3) m/s2, 
dB, g
Gain
auto
,х1, х2, 
х4, х5, х8, 
х10, х16, 
х32
-
auto
,х1, х2, 
х4, х5, х8, 
х10, х16, 
х32
auto
,х1, х2, 
х4, х5, х8, 
х10, х16, 
х32
auto
,х1, х2, 
х4, х5, х8, 
х10, х16, 
х32
auto
,х1, х2, 
х4, х5, х8, 
х10, х16, 
х32
Averaging
1-100
-
1-100
-
1-100
1-100
Parameter
RMS
Peak
Peak- Peak
Crest factor
Kurtosis
-
-
-
-
RMS
Peak
Peak- Peak
Band
2-200,
2-1000,
10-1000,
10-2000,
10-10000
-
-
-
-
-
Samples
-
512, 1024,
1536,
2048,
2560,
3072,
3584, 4096
-
4096
-
-
Fmax.Hz
-
200, 500,
1000,
2000,
5000,
10000
200, 500,
1000,
2000,
5000,
10000
200, 500,
1000
200, 500,
1000
-
Start up
-
auto
tacho
manual
-
-
-
-
BFP f0,
Hz
-
-
-
4000,
5000,
6300,
8000
4000,
5000,
6300,
8000
-
Filter
type
-
-
-
1/1 octave,
2/3 octave,
1/3 octave,
1/1 octave,
2/3 octave,
1/3 octave,
-
axis X
-
-
log, lin
-
log, lin
-
axis Y
-
-
log, lin
-
log, lin
-
Fmin, Hz
-
-
0-180
(interval 
20)
-
0-900
(interval 
100)
-
Lines
-
-
400, 800,
1600
-
1600
-
Window
-
-
Hanning
Rectangle
lackman-h
-
Hanning
Rectangle
Blackman-h
-
Mode
-
-
-
-
-
tach
strobe
Harmonic
-
-
-
-
-
1-10
Function
Overall
Time
waveform
Spectrum
Envelope
Envelope
spectrum
Peak and
phase

Table of Contents