Banner AG4 Series Safety Laser Scanner
be configured for a minimum of 80 ms to a maximum of 640 milliseconds (default = 160 ms). See Section 4 or the
AG4Soft manual for more information.
Alarm 1 (Auxiliary 1) output (X1 – 5) is configurable to provide status of the following; output turns OFF when:
None (output is held OFF)
Device Warning (lockout condition or dirty window indication, i.e. LED 5 is flashing)
Warning Field interrupted (automatic reset only, default)
Device Warning or Warning Field interrupted
Alarm 2 (Auxiliary 2) output (X1 – 15) provides the Device Warning function, which signals a lockout condition or dirty
window indication (i.e. LED 5 is flashing) by turning OFF the output.
See Figures 3-18, 3-19, and 3-20 for hookup (wiring) information.
Important Note: The alarm (auxiliary) outputs are not safety-rated and should be used only for
non-safety-related diagnostic or system-monitoring purposes.