Banner AG4 Series Safety Laser Scanner
5.1.2 Scanner Error Codes
A diagnostics list can be created with the AG4Soft software. The incidents that occurred during the Scanner operation
are listed in this diagnostics list. Each incident is given with place and number. The meaning of the incidents is shown in
the following table. To access diagnostic information highlight the ―System Data‖ Operating tab and click on menu bar
path ―System Data > Display the Scanner’s diagnostics list‖.
Table 11. Diagnostics codes
Place
Number
Meaning
Activity
102
2
Data transfer error on interface X2.
Check the interface parameters and start the transfer again.
103
2
Data transfer error on interface X2.
Check the interface parameters and start the transfer again.
104
2
Data transfer error on interface X2.
Check the interface parameters and start the transfer again.
105
6
Function, access, command not allowed with currently
selected authorization level.
Change the authorization level and start the transfer again.
201
4
Interface X2 time specifications not complied with, last
message overwritten.
Check the interface parameters and start the transfer again.
302
2
Interface X2 time specifications not complied with,
send data not acknowledged.
Check the interface parameters and start the transfer again.
306
5
Previous message not completely issued, interface X2
time specifications not complied with.
Check the interface parameters and start the transfer again.
801
2
Error memory cannot be read, internal defect.
If reset is not successful, contact customer service
805
6
Error memory cannot be transferred, transfer error on
interface X2.
Check the interface parameters and start the transfer again.
1002
1
Motor does not reach the nominal speed after start,
internal defect.
If reset is not successful, contact customer service
1002
2
Motor speed not constant after start, internal defect.
If reset is not successful, contact customer service
1003
1
Motor does not reach the nominal speed after start,
internal defect.
If reset is not successful, contact customer service
1003
2
Motor speed not constant after start, internal defect.
If reset is not successful, contact customer service
1003
3
Motor speed not constant after start, time exceeded.
If reset is not successful, contact customer service