Banner AG4 Series Safety Laser Scanner
Protective Field – The Scanner effective Separation (safety) distance/Safety distance that is required to stop the machine before a person who
enters the Protective Field reaches the machine and is specified in ISO 13855 and associated standards.
Response Time – The time between the interruption by the System OSSDs and the instant when the dangerous parts of the machine reach a safe
state by being brought to rest.
Qualified Person – A person or persons who, by possession of a recognized degree or certificate of professional training, or who, by extensive
knowledge, training, and experience, has successfully demonstrated the ability to solve problems relating to the subject matter and work.
Response Time – The time between the physical initiation of the safety device and the machine coming to a stop or the risk being removed.
Trip Condition – In trip output models, the response of the FSD relays when an object equal to or greater than the diameter of the specified test
piece enters the Protective Field. In a trip condition, FSD 1 and FSD 2 simultaneously de-energize and open their contacts. A trip condition clears
automatically when the object is removed from the Protective Field.
User – An entity that utilizes a machine or related equipment. The user is typically regarded as the entity that employs the operator of the machine
and/or supervises the operation of the machine, including production and maintenance.