Note: Assembly Instance 100 does not provide barcode data.
WORD # WORD NAME DATA TYPE
0 Input Bits ACK Register (see
Input and Output Flags Bits
(p. 106)) 16-bit integer
1 Output Bits Register (see
Input and Output Flags Bits
(p. 106)) 16-bit integer
2-3 Error Code 32-bit integer
4-5 Inspection Number 32-bit integer
6-7 Iteration Count 32-bit integer
8-9 Pass Count 32-bit integer
10-11 Fail Count 32-bit integer
12-13 Missed Triggers 32-bit integer
14-15 Current Inspection Time Float
16 Sensor P/F Coil 16-bit integer
17-29
reserved
16-bit integer
PLC Assembly Instance 101 (0×65) - 240 Registers (iVu BCR Outputs/PLC
Inputs)
Assembly Instance 101 provides space for a single block of barcode data (up to ASCII characters in length) as well as
space for Command Channel replies.
WORD # WORD NAME DATA TYPE
0 Input Bits ACK Register (see
Input and Output Flags Bits
(p. 106)) 16-bit integer
1 Output Bits Register (see
Input and Output Flags Bits
(p. 106)) 16-bit integer
2-3 Error Code 32-bit integer
4-5 Inspection Number 32-bit integer
6-7 Iteration Count 32-bit integer
8-9 Pass Count 32-bit integer
10-11 Fail Count 32-bit integer
12-13 Missed Triggers 32-bit integer
14-15 Current Inspection Time Float
16 Sensor Pass/Fail Coil 16-bit integer
17-29
reserved
16-bit integer
30-52 Inspection Name 2-Word Length + 20-unicode characters
53-54 Frame Number 32-bit integer
55 Sensor Type ID 16-bit integer
56 Barcode Count 16-bit integer
57 Barcode-1 Type 16-bit integer
58 Barcode-1 Actual Decoded Data Length 16-bit integer
59-60 Barcode-1 Data Array Length 32-bit integer
61-162 Barcode-1 Data Array 100 Byte Array
163-170
reserved
16-bit integer
171 Command Status 16-bit integer
iVu Plus BCR Gen2 Series Sensor