Table 37: 128-Byte First Barcode Submodule (Ident 0x00022)
PLC Input Data Name Input Data Type
Frame number Unsigned32
Sensor type Unsigned16
Total number of barcodes found Unsigned16
Barcode 1 type Unsigned16
Actual length of barcode 1 data Unsigned16
Output length of barcode 1 data Unsigned32
128-character barcode output string 128-byte OctetString
PLC Output Data Name Output Data Type
Not applicable Not applicable
Table 38: 256-Byte First Barcode Submodule (Ident 0x00023)
PLC Input Data Name Input Data Type
Frame number Unsigned32
Sensor type Unsigned16
Total number of barcodes found Unsigned16
Barcode 1 type Unsigned16
Actual length of barcode 1 data Unsigned16
Output length of barcode 1 data Unsigned32
256-character barcode output string 256-byte OctetString
PLC Output Data Name Output Data Type
Not applicable Not applicable
Table 39: 512-Byte First Barcode Submodule (Ident 0x00024)
PLC Input Data Name Input Data Type
Frame number Unsigned32
Sensor type Unsigned16
Total number of barcodes found Unsigned16
Barcode 1 type Unsigned16
Actual length of barcode 1 data Unsigned16
Output length of barcode 1 data Unsigned32
512-character barcode output string 512-byte OctetString
PLC Output Data Name Output Data Type
Not applicable Not applicable
The Multiple Barcodes Submodule is predefined and contains barcode output data. This submodule has space for ten
individual barcodes.
iVu Plus BCR Gen2 Series Sensor
136 www.bannerengineering.com - Tel: + 1 888 373 6767