EasyManua.ls Logo

Banner iVu Plus BCR Gen2 Series - Page 135

Banner iVu Plus BCR Gen2 Series
203 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Sensor Output Submodules
The First Barcode Submodule contains barcode output data. This user-enabled submodule is optional and plugged into
Slot 2 Subslot 1. The First Barcode Submodule has six versions with 16, 32, 64, 128, 256, and 512 bytes, depending on the
length of the output string.
Table 34: 16-Byte First Barcode Submodule (Ident 0x00019)
PLC Input Data Name Input Data Type
Frame Number Unsigned32
Sensor type Unsigned16
Total number of barcodes found Unsigned16
Barcode 1 type Unsigned16
Actual length of barcode 1 data Unsigned16
Output length of barcode 1 data Unsigned32
16-character barcode output string 16-byte OctetString
PLC Output Data Name Output Data Type
Not applicable Not applicable
Table 35: 32-Byte First Barcode Submodule (Ident 0x00020)
PLC Input Data Name Input Data Type
Frame number Unsigned32
Sensor type Unsigned16
Total number of barcodes found Unsigned16
Barcode 1 type Unsigned16
Actual length of barcode 1 data Unsigned16
Output length of barcode 1 data Unsigned32
32-character barcode output string 32-byte OctetString
PLC Output Data Name Output Data Type
Not applicable Not applicable
Table 36: 64-Byte First Barcode Submodule (Ident 0x00021)
PLC Input Data Name Input Data Type
Frame number Unsigned32
Sensor type Unsigned16
Total number of barcodes found Unsigned16
Barcode 1 type Unsigned16
Actual length of barcode 1 data Unsigned16
Output length of barcode 1 data Unsigned32
64-character barcode output string 64-byte OctetString
PLC Output Data Name Output Data Type
Not applicable Not applicable
iVu Plus BCR Gen2 Series Sensor