Sensor Output Submodules
The First Barcode Submodule contains barcode output data. This user-enabled submodule is optional and plugged into
Slot 2 Subslot 1. The First Barcode Submodule has six versions with 16, 32, 64, 128, 256, and 512 bytes, depending on the
length of the output string.
Table 34: 16-Byte First Barcode Submodule (Ident 0x00019)
PLC Input Data Name Input Data Type
Frame Number Unsigned32
Sensor type Unsigned16
Total number of barcodes found Unsigned16
Barcode 1 type Unsigned16
Actual length of barcode 1 data Unsigned16
Output length of barcode 1 data Unsigned32
16-character barcode output string 16-byte OctetString
PLC Output Data Name Output Data Type
Not applicable Not applicable
Table 35: 32-Byte First Barcode Submodule (Ident 0x00020)
PLC Input Data Name Input Data Type
Frame number Unsigned32
Sensor type Unsigned16
Total number of barcodes found Unsigned16
Barcode 1 type Unsigned16
Actual length of barcode 1 data Unsigned16
Output length of barcode 1 data Unsigned32
32-character barcode output string 32-byte OctetString
PLC Output Data Name Output Data Type
Not applicable Not applicable
Table 36: 64-Byte First Barcode Submodule (Ident 0x00021)
PLC Input Data Name Input Data Type
Frame number Unsigned32
Sensor type Unsigned16
Total number of barcodes found Unsigned16
Barcode 1 type Unsigned16
Actual length of barcode 1 data Unsigned16
Output length of barcode 1 data Unsigned32
64-character barcode output string 64-byte OctetString
PLC Output Data Name Output Data Type
Not applicable Not applicable
iVu Plus BCR Gen2 Series Sensor
www.bannerengineering.com - Tel: + 1 888 373 6767 135