Table 43: 64-Byte Compare String Submodule (Ident 0x0006)
PLC Input Data Name Input Data Type
Return status code of the string or
mask-set operation
Unsigned16
String or mask-set operation error
code
Unsigned32
Return Status Code of the String or Mask-Set Operation
Bit Position for Cyclic Input Data Function
Bit 0 Set Barcode Compare String
Acknowledgement
Bit 1 Set Barcode Compare Mask
Acknowledgement
PLC Output Data Name Output Data Type
BCR control word Unsigned16
Reserved Unsigned16
Length-of-barcode compare string or
mask, up to 64 characters
Unsigned32
Maximum 64-character barcode
compare string or mask
64-byte OctetString
BCR Control Word
Bit Position for Cyclic Output Data Function
Bit 0 Set Barcode Compare String
Request
Bit 1 Set Barcode Compare Mask
Request
Table 44: 128-Byte Compare String Submodule (Ident 0x0007)
PLC Input Data Name Input Data Type
Return status code of the string or
mask-set operation
Unsigned16
String or mask-set operation error
code
Unsigned32
Return Status Code of the String or Mask-Set Operation
Bit Position for Cyclic Input Data Function
Bit 0 Set Barcode Compare String
Acknowledgement
Bit 1 Set Barcode Compare Mask
Acknowledgement
PLC Output Data Name Output Data Type
BCR control word Unsigned16
Reserved Unsigned16
Length-of-barcode compare string or
mask, up to 128 characters
Unsigned32
Maximum 128-character barcode
compare string or mask
128-byte OctetString
BCR Control Word
Bit Position for Cyclic Output Data Function
Bit 0 Set Barcode Compare String
Request
Bit 1 Set Barcode Compare Mask
Request
iVu Plus BCR Gen2 Series Sensor
www.bannerengineering.com - Tel: + 1 888 373 6767 139