Table 45: 256-Byte Compare String Submodule (Ident 0x0008)
PLC Input Data Name Input Data Type
Return status code of the string or
mask-set operation
Unsigned16
String or mask-set operation error
code
Unsigned32
Return Status Code of the String or Mask-Set Operation
Bit Position for Cyclic Input Data Function
Bit 0 Set Barcode Compare String
Acknowledgement
Bit 1 Set Barcode Compare Mask
Acknowledgement
PLC Output Data Name Output Data Type
BCR control word Unsigned16
Reserved Unsigned16
Length-of-barcode compare string or
mask, up to 256 characters
Unsigned32
Maximum 256-character barcode
compare string or mask
256-byte OctetString
BCR Control Word
Bit Position for Cyclic Output Data Function
Bit 0 Set Barcode Compare String
Request
Bit 1 Set Barcode Compare Mask
Request
Table 46: 512-Byte Compare String Submodule (Ident 0x0009)
PLC Input Data Name Input Data Type
Return status code of the string or
mask-set operation
Unsigned16
String or mask-set operation error
code
Unsigned32
Return Status Code of the String or Mask-Set Operation
Bit Position for Cyclic Input Data Function
Bit 0 Set Barcode Compare String
Acknowledgement
Bit 1 Set Barcode Compare Mask
Acknowledgement
PLC Output Data Name Output Data Type
BCR control word Unsigned16
Reserved Unsigned16
Length-of-barcode compare string or
mask, up to 512 characters
Unsigned32
Maximum 512-character barcode
compare string or mask
512-byte OctetString
BCR Control Word
Bit Position for Cyclic Output Data Function
Bit 0 Set Barcode Compare String
Request
Bit 1 Set Barcode Compare Mask
Request
Command Channel Command Submodules
The Command Channel Command Submodules contain controller (PLC) output data and command channel request data.
The user-enabled submodules are optional. On the iVu Plus BCR Gen2 device the submodule is plugged into Slot 4 Subslot
1.
The Command Channel Command Submodule has four versions, depending on the required length of the input string.
iVu Plus BCR Gen2 Series Sensor