Figure 152. Install GSD Files Screen
The Install GSD Files window displays.
6. Browse to the location of the saved Banner iVu BCR GSD file.
7. Select the version of the file you want to add and click Install to add the GSD file to the Hardware catalog.
8. Go to the View menu in the Hardware
configuration window.
9. Check the Catalog option.
The Hardware catalog appears on the right side of the Hardware
configuration window.
Figure 153. Hardware Catalog
The location in the Hardware catalog is PROFINET IO > Additional Field Devices > Sensors > Banner Vision Sensors
> iVu Series
Creating a PROFINET
®
Connection
Use these instructions to create a PROFINET Connection in Hardware configuration with the Siemens SIMATIC STEP 7
(v5.5) software.
iVu Plus BCR Gen2 Series Sensor