Command Command ID Description Data Type
Do Set Get
Trigger
Trigger Mode 1 10001 The iVu BCR triggering mode. This value must match the
modes supported by the iVu BCR.
Int16
Product Change
Product Change By
Name
21 This command forces the iVu BCR to switch to the
specified inspection. The iVu BCR does not transmit a
response until the iVu BCR has completed the action.
Inspection results immediately after a product change
are invalid until a new trigger is received.
Byte Array
Imager
Gain 51 10051 The iVu BCR value used to electronically brighten all
image pixels.
Int32
Exposure 52 10052 The iVu BCR value used to control the amount of time
the imager is allowed to gather light for the image.
Int32
Status
Clear System Error 81 This command clears the system error LED and resets
the internal system error flag to false.
N/A
System
Reboot Sensor 101 This command restarts the iVu BCR. If the iVu BCR
configuration data is currently being saved, this
command is blocked until the save operation completes.
N/A
Save Configuration 102 This command saves all modified inspection and
configuration parameters. This command blocks all other
commands until all values have been persisted.
N/A
Info
Sensor Name 10151 User-assigned device name. Byte Array
Model Number 10152 Device model number. Byte Array
Serial Number 10153 Device serial number. Byte Array
Firmware Version 10154 Device firmware (software) version. Byte Array
Hour Counter 10155 The total number of hours the device has been
energized.
Byte Array
History
Clear History 301 This command clears all history fields for the active
inspection. History values include pass count, fail count,
execution times and sensor-specific history values.
N/A
Inspection
Inspection Name 10501 The name of the active inspection. Byte Array
BCR inputs
Compare String 11001 The Barcode inspection compare data string. This string
must start and end with the double quote character.
Byte Array
Compare Mask 11002 The Barcode inspection compare string mask in binary
format, that is, masked characters are indicated by a "1"
and unmasked characters are "0." Note that the mask
character string must match the length of the compare
string.