Error Code Description Recommended Solution
10027 The connection to the sensor was
lost.
Verify the sensor is energized
Verify the sensor communication cable is connected
Verify all inline network equipment is energized, properly
configured and connected
Verify all required network equipment cables are connected
Verify the network adaptor is properly
configured
Verify the sensor IP address is valid
Verify there are no other devices using the same IP address
Verify the sensor subnet is valid
Verify the sensor can be successfully pinged
Verify the network
firewall settings support connection to the
sensor
10040 The device at the specified IP
address is already connected to
another application. This can
happen when another Vision
Manager is already connected to
the sensor.
Disconnect the other application and try again
Verify there are no other devices using the same IP address
10041 The device at the specified IP
address rejected the connection
attempt. This can happen when the
network device does not support
the Vision Manager protocol.
Verify the sensor's firmware version is compatible with this
application
Verify the device at the specified IP address is a Banner Vision
sensor
10050 The connection to the sensor was
lost.
Verify the sensor is energized
Verify the sensor communication cable is connected
Verify all inline network equipment is energized, properly
configured and connected
Verify all required network equipment cables are connected
Verify the network adaptor is properly
configured
Verify the sensor IP address is valid
Verify there are no other devices using the same IP address
Verify the sensor subnet is valid
Verify the sensor can be successfully pinged
Verify the network
firewall settings support connection to the
sensor
10051 The connection to the sensor was
lost.
Verify the sensor is energized
Verify the sensor communication cable is connected
Verify all inline network equipment is energized, properly
configured and connected
Verify all required network equipment cables are connected
Verify the network adaptor is properly
configured
Verify the sensor IP address is valid
Verify there are no other devices using the same IP address
Verify the sensor subnet is valid
Verify the sensor can be successfully pinged
Verify the network
firewall settings support connection to the
sensor
10053 The connection to the sensor was
lost while receiving data.
Verify the sensor is energized
Verify the sensor communication cable is connected
Verify all inline network equipment is energized, properly
configured and connected
Verify all required network equipment cables are connected
Verify the network adaptor is properly
configured
Verify the sensor IP address is valid
Verify there are no other devices using the same IP address
Verify the sensor subnet is valid
Verify the sensor can be successfully pinged
Verify the network
firewall settings support connection to the
sensor