4. Physical Installation
4. PHYSICAL INSTALLATION
About
This chapter describes the physical c onditions and procedures required w hen installing the F70 pro jector. It also describes the
outlines and some of the co nsiderations that should be taken in to account w hen designing and setting up the installation.
Each projector installation is unique, and as such the information in t his chap ter is only p rovided as a guideline. Likewise, any images
or g raphical representations shown here are for illustrative purposes only.
If you re quire further information and assistance during the installation process, contact a qualified projection technician or your local
support office for advice.
Overview
• Installation Process
• Installation conditions
• Initial inspection
• Positioning the projector
• Mounting the projector, general considerations
• Projector safe attachment points
• Throw distance
• Scheimpflug (Boresight) adjustment
• Scheimpflug adjustment procedure
4.1 Installation P ro ce ss
Recommended Installation sequence
Item Procedure Read more in chapter
1
Confirm that the installation area meets all
technical and environmental requirements
To be linked to a chapter and page
2 Decide w here the pr ojector will be mounted To be linked to a chapter and page
3
Unpack the projector and confirm that all
equipment is present and in good working
order
To be linked to a chapter and page
4 Mount the projector To be linked to a chapter and page
5 Install the projector lens To be linked to a chapter and page
6
Connect the source
To be linked to a chapter and page
7 Power up the projector To be linked to a chapter and page
8
Set up the image
To be linked to a chapter and page
4.2 Installation c onditions
Environmental Conditions
Barco projectors are m anu factured according to s pecific design standards, w hich also include en vironmental
conditions. Failing to follow the terms and conditions outlined in this chapter can result in loss of product
warranty
The table below summar ize the physical environments in which the projector may be safely operated or stored.
Environmen t Amb ient operating
temperature
Relative Humidity
Storage condition
0 -500m
+10 to +45 °C 10 –80% RH –20 to +60 °C, 10 – 9 0 % RH
500 -1500m
+10 to +40 °C 10 –80% RH –20 to +60 °C, 10 – 9 0 % RH
1500 - 3000m
+10 to +35°C 10 –80% RH –20 to +60 °C, 10 – 9 0 % RH
Maximum Air Flow
900m
3
/hour 10 –80% RH
Not Applicable
601–426 F70 SERIES 16/06/2017 31