Lamp replacement
The lifecycle of ordinary projection lamp 
typically lasts for 1500-2000 hours before 
requiring replacement (different lamp 
configurations will affect lamp life). From the 
OSD Menu, you can go to LAMPS  Lamp1 
or 2 Run Time to check how long a lamp has 
been used. You should also replace the lamp 
when the projected image gets noticeably 
darker. Contact your local dealer to purchase 
new certified lamps for your projector.
To replace the projector lamp
1.   Turn off the projector and unplug 
the power cord. Let the projector 
cool for approximately 60 minutes 
before removing the lamp module for 
replacement.
   When you turn off the projector, the lamp 
inside the projector will still be very hot 
(approximately 200 ~ 300°C). If you attempt to 
replace the lamp without allowing the projector 
to cool, you could risk scalding yourself. This 
is why you should wait for no less than 60 
minutes for the lamp to cool down in order to 
perform the replacement safely.
2.   Loosen the lamp cover. 
Loose the 
two screws
3.   Use a screw driver to loosen the 
screws as shwon in the illustration.  
loosen the 
two screws
4.   Grasp the metal rod on the lamp 
cover and pull the lamp out. 
5.   Insert the new lamp in the direction 
shown in the illustration into the lamp 
assembly; tighten the two screws 
using a screw diver and make sure 
the lamp is rmly secured to prevent 
the lamp from shaking or poor 
contact.  
6.   Replace the lamp cover and rmly 
secure the two screws on the lamp 
cover. 
Tightly lock the 
two screws
7.   Reconnect power to the projector and 
reset the lamp usage timer. Refer to 
OSD Menu description 
 Service 
 
Lamp1, 2 Run Time.