Standard Features AW00097603000
210 Basler aviator GigE
Note also that the camera briefly exits the "waiting for frame start trigger" status while an input
line changes its state. This happened when input line 1 changed its state before the second
frame start trigger was received (see also Figure 48).
When the next frame start trigger is received, the camera checks the state of input line 1. Input
line 1 is found to be low and therefore no new sequence parameter values are loaded into the
active set. The parameter values of sequence set 1 are used for the image acquisition.
When the next frame start trigger is received, the camera checks the state of input line 1. Input
line 1 is found to be low and therefore no new sequence parameter values are loaded into the
active set. The parameter values of sequence set 1 are used for the image acquisition.
When the next frame start trigger is received, the camera checks the state of input line 1. Input
line 1 is found to be high and therefore the parameter values of the next sequence set are
loaded into the active set. The parameter values of sequence set 2 are used for the image
acquisition.
When the next frame start trigger is received, the camera checks the state of input line 1. Input
line 1 is found to be high and therefore the parameter values of the next sequence set are
loaded into the active set. The parameter values of sequence set 3 are used for the image
acquisition.
When the next frame start trigger is received, the camera checks the state of input line 1. Input
line 1 is found to be high and therefore the parameter values of the next sequence set are
loaded into the active set. The parameter values of sequence set 4 are used for the image
acquisition.
When the next frame start trigger is received, the camera checks the state of input line 1. Input
line 1 is found to be high and therefore the parameter values of the next sequence set are
loaded into the active set. The parameter values of sequence set 5 are used for the image
acquisition.
When the next frame start trigger is received, the camera checks the state of input line 1. Input
line 1 is found to be low and therefore no new sequence parameter values are loaded into the
active set. The parameter values of sequence set 5 are used for the image acquisition.
The camera has cycled once through the complete sequence set cycle.
When the next frame start trigger is received, the camera checks the state of input line 1. Input
line 1 is found to be high and therefore the parameter values of the next sequence set are
loaded into the active set. The parameter values of sequence set 0 are used for the image
acquisition.
Make sure not to send a frame start trigger while the input line changes its
state. During this period, the camera will not wait for a frame start trigger and
any frame start trigger will be ignored.
Make sure to only send a frame start trigger when the camera is in "waiting for
frame start trigger" status.
For information about possibilities of getting informed about the "waiting for
frame trigger" status, see the Acquisiton Monitoring Tools section.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Basler GigE CAMERAS and is the answer not in the manual?

Basler GigE CAMERAS Specifications

General IconGeneral
BrandBasler
ModelGigE CAMERAS
CategoryDigital Camera
LanguageEnglish

Related product manuals