AW00097603000 Standard Features
Basler aviator GigE 227
10.10.3.2 Configuration
Configuring Sequence Sets and Advance Control
Use the following procedure for populating sequence sets and setting the source for sequence set
advance:
1. Make sure that the sequencer feature is disabled.
2. Set the Sequence Advance Mode parameter to Free Selection.
3. Set the Sequence Set Total Number parameter. The maximum number is 4.
4. Select the sequence set address bits and set the input lines that will act as the control sources:
If the Set Total Number parameter was set to two:
a. Bit 0 will be selected by default as the sequence set address bit. Set input line 1 or input
line 2 as the control source for setting bit 0.
If the Set Total Number parameter was set to higher than two:
a. Select bit 0 of the sequence set address bit.
b. Set input line 1 or input line 2 as the control source for setting bit 0.
c. Select bit 1 of the sequence set address bit.
d. Set the input line as the control source for setting bit 1: Chose the input line not used for
setting bit 0.
5. Use the Sequence Set Index parameter to select a sequence set index number for the
sequence set currently being populated. The available numbers are 0 through 3.
6. Set up your first acquisition scenario (i.e., lighting, object positioning, etc.)
7. Adjust the camera parameters to get the best image quality with this scenario (you are
adjusting the parameters in the active set).
8. Execute the Sequence Set Store command to copy the sequence parameter values currently
in the active set into the selected sequence set. (Any existing parameter values in the
sequence set will be overwritten.)
9. Repeat the above steps for the other sequence sets, starting from step 5.
Configuring Sequence Sets and Advance Control Using Basler pylon
You can use the pylon API to set the parameters for configuring sequence sets from within your
application software and make settings for their selection when images are acquired.
The following code snippet gives example settings. It illustrates using the API to set the free
selection sequence advance mode with line 1 as the control source for bit 0 and line 2 as the control
source for bit 1 of the sequence set address, set the total number of sequence sets to 3, and
populate sequence sets 0 through 2 by storing the sequence parameter values from the active set
in the sequence sets:
// Disable the sequencer feature
Camera.SequenceEnable.SetValue( false );