Image Acquisition Control AW00011916000
110 Basler scout GigE
Camera.AcquisitionStart.Execute( );
You can also use the Basler pylon Viewer application to easily set the parameters.
For more information about the pylon Viewer, see Section 3.1 on page 43.
When the camera's acquisition mode is set to single frame, the maximum possible
acquisition frame rate for a given AOI cannot be achieved. This is true because
the camera performs a complete internal setup cycle for each single frame and
because it cannot be operated with "overlapped" exposure (the scA750-60 does
not allow "overlapped" exposure on principle).
To achieve the maximum possible acquisition frame rate set the camera for the
continuous acquisition mode. And for all models except scA750-60 also use
"overlapped" exposure.
For more information about overlapped exposure, see Section 9.9 on page 153.