Image Acquisition Control AW00011916000
114 Basler scout GigE
9.4.3 Setting the Acquisition Start Trigger Mode and
Related Parameters (Standard Mode)
You can set the Trigger Mode and Trigger Source parameters for the acquisition start trigger and
also set the Acquisition Frame Count parameter value from within your application software by
using the Basler pylon API.
The following code snippet illustrates using the API to set the Trigger Mode to on, the Trigger
Source to software, and the Acquisition Frame Count to 5:
// Set the acquisition mode to continuous(the acquisition mode must
// be set to continuous when acquisition start triggering is on)
Camera.AcquisitionMode.SetValue( AcquisitionMode_Continuous );
// Select the acquisition start trigger
Camera.TriggerSelector.SetValue( TriggerSelector_AcquisitionStart );
// Set the mode for the selected trigger
Camera.TriggerMode.SetValue( TriggerMode_On );
// Set the source for the selected trigger
Camera.TriggerSource.SetValue ( TriggerSource_Software );
// Set the acquisition frame count
Camera.AcquisitionFrameCount.SetValue( 5 );
The following code snippet illustrates using the API to set the Trigger Mode to on, the Trigger
Source to line 1, the Trigger Activation to rising edge, and the Acquisition Frame Count to 5:
// Set the acquisition mode to continuous(the acquisition mode must
// be set to continuous when acquisition start triggering is on)
Camera.AcquisitionMode.SetValue( AcquisitionMode_Continuous );
// Select the acquisition start trigger
Camera.TriggerSelector.SetValue( TriggerSelector_AcquisitionStart );
// Set the mode for the selected trigger
Camera.TriggerMode.SetValue( TriggerMode_On );
// Set the source for the selected trigger
Camera.TriggerSource.SetValue ( TriggerSource_Line1 );
// Set the activation mode for the selected trigger to rising edge
Camera.TriggerActivation.SetValue( TriggerActivation_RisingEdge );
// Set the acquisition frame count
Camera.AcquisitionFrameCount.SetValue( 5 );
You can also use the Basler pylon Viewer application to easily set the parameters.
For more information about the pylon Viewer, see Section 3.1 on page 43.