12.5.2 Controlled Sequence Advance Mode
When the controlled sequence advance mode is selected the advance from one sequence set to
the next proceeds in ascending sequence set index numbers according to the selected sequence
control source:
Always Active: The advance from one sequence set to the next proceeds automatically as
frame triggers are received.
Input Line 1 or Input Line 2: The advance from one sequence set to the next proceeds
according to the states of the selected input line.
Disabled: The advance from one sequence set to the next is only controlled by AsyncAdvance
software commands.
The Sequence Set Total Number parameter specifies the total number of different sequence sets
that are available and included within a sequence set cycle. The maximum number is 64.