AW00011916000 Image Acquisition Control
Basler scout GigE 161
Selecting the Trigger Ready Signal as the Source Signal for an Output Line
The trigger ready signal can be selected to act as the source signal for e.g.output line 1. Selecting
a source signal for the output line is a two step process:
Use the Line Selector to select output line 1.
Set the value of the Line Source Parameter to the trigger ready output signal.
You can set the Line Selector and the Line Source parameter value from within your application
software by using the Basler pylon API. The following code snippet illustrates using the API to set
the selector and the parameter value:
Camera.LineSelector.SetValue( LineSelector_Out1 );
Camera.LineSource.SetValue( LineSource_TriggerReady );
You can also use the Basler pylon Viewer application to easily set the parameters.
For more information about changing the assignment of camera output signals to physical output
lines, see Section 8.2.1 on page 93.
For more information about the electrical characteristics of the camera’s output lines, see
Section 7.7.2 on page 87.
For more information about the standard and legacy image acquisition control modes, see
Section 9.1 on page 103.