AW00011916000 Image Acquisition Control
Basler scout GigE 169
Formula 2:
Calculates the maximum frame rate based on the exposure time for the acquired frames:
Where the constant C
3
depends on the camera model as shown in the table below:
For more information about setting the exposure time, see Section 9.7 on page 141.
Formula 3:
Calculates the maximum frame rate based on the frame transmission time:
Camera Model C
1
C
2
Camera Model C
1
C
2
scA640-70gm/gc 25.49 µs 1612.86 µs scA1390-17gm/gc 46.53 µs 10244.54 µs
scA640-74gm/gc 22.66 µs 1433.66 µs scA1400-17gm/gc 46.53 µs 9357.50 µs
scA640-120gm/gc 14.16 µs 1128.80 µs scA1400-30gm/gc 25.80 µs 6418.04 µs
scA780-54gm/gc 26.94 µs 2308.54 µs scA1600-14gm/gc 50.99 µs 6658.82 µs
scA1000-30gm/gc 35.39 µs 4507.20 µs scA1600-28gm/gc 26.62 µs 2870.54 µs
scA1300-32gm/gc 28.65 µs 2806.10 µs
Camera Model C
3
Camera Model C
3
scA640-70gm/gc 95 µs scA1390-17gm/gc 177 µs
scA640-74gm/gc 84 µs scA1400-17gm/gc 175 µs
scA640-120gm/gc 24 µs scA1400-30gm/gc 97 µs
scA780-54gm/gc 100 µs scA1600-14gm/gc 176 µs
scA1000-30gm/gc 132 µs scA1600-28gm/gc 95.23 µs
scA1300-32gm/gc 54 µs
Max. Frames/s
Device Current Throughput Parameter Value
Payload Size Parameter Value
------------------------------------------------------------------------------------------------------------------------=