EasyManua.ls Logo

Basler scout GigE - Page 179

Basler scout GigE
374 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AW00011916000 Image Acquisition Control
Basler scout GigE 169
Formula 2:
Calculates the maximum frame rate based on the exposure time for the acquired frames:
Where the constant C
3
depends on the camera model as shown in the table below:
For more information about setting the exposure time, see Section 9.7 on page 141.
Formula 3:
Calculates the maximum frame rate based on the frame transmission time:
Camera Model C
1
C
2
Camera Model C
1
C
2
scA640-70gm/gc 25.49 µs 1612.86 µs scA1390-17gm/gc 46.53 µs 10244.54 µs
scA640-74gm/gc 22.66 µs 1433.66 µs scA1400-17gm/gc 46.53 µs 9357.50 µs
scA640-120gm/gc 14.16 µs 1128.80 µs scA1400-30gm/gc 25.80 µs 6418.04 µs
scA780-54gm/gc 26.94 µs 2308.54 µs scA1600-14gm/gc 50.99 µs 6658.82 µs
scA1000-30gm/gc 35.39 µs 4507.20 µs scA1600-28gm/gc 26.62 µs 2870.54 µs
scA1300-32gm/gc 28.65 µs 2806.10 µs
Camera Model C
3
Camera Model C
3
scA640-70gm/gc 95 µs scA1390-17gm/gc 177 µs
scA640-74gm/gc 84 µs scA1400-17gm/gc 175 µs
scA640-120gm/gc 24 µs scA1400-30gm/gc 97 µs
scA780-54gm/gc 100 µs scA1600-14gm/gc 176 µs
scA1000-30gm/gc 132 µs scA1600-28gm/gc 95.23 µs
scA1300-32gm/gc 54 µs
Max. Frames/s
1
Exposure time in µs C
3
+
--------------------------------------------------------------------=
Max. Frames/s
Device Current Throughput Parameter Value
Payload Size Parameter Value
------------------------------------------------------------------------------------------------------------------------=

Table of Contents

Related product manuals