Setting the B-TIMER
The following values can be set on the B-TIMER:
Enter the numbers of filter cartridges used
Set the delivery volume
Set the operating pressure
Set the operating hours
After changing the set values, the B-TIMER must be reset.
1.
Invoke the display of cartridge number to access the setup menu.
2.
Press the selection key and the input key on the display simultaneously for
longer than 5 seconds.
Ä
The filter icon blinks and shows the setup menu.
Press the selection key twice to return to the main menu.
Setting the filter cartridge number
1.
In the setup mode, press the selection key until the corresponding sub-menu
is reached.
Ä
The filter icon blinks and "A" is shown.
2.
Refer to the order documents for the number of the filter cartridge used.
3.
Press the input key for 3 seconds if you want to change the setting.
Ä
The filter cartridge number starts blinking.
4.
Use the selection key to select the desired filter cartridge number.
- Or -
For filter cartridge numbers that start with 999: Select 999000 using the se-
lection key. Then set the respective flashing zero using the selection key and
always confirm the changes using the input key.
5.
Confirm the change using the input key.
OPERATING MANUAL Commissioning and operation | 7
28.08.2019
A_002_en