EasyManua.ls Logo

Bauer POSEIDON PE 200-TB - Page 74

Bauer POSEIDON PE 200-TB
150 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setting the delivery volume
1.
In the setup mode, press the selection key until the corresponding sub-menu
is reached.
Ä
The filter icon blinks and “B" is shown.
2.
Refer to the order documents for the delivery volume of the compressor in l/
min.
3.
Press the input key for 3 seconds if you want to change the setting.
Ä
The 1stposition starts blinking.
4.
Use the selection key to set the 1stposition as desired.
5.
Confirm the change using the input key.
Ä
The 2ndposition starts blinking.
6.
Set the 2nd and 3rdpositions accordingly.
Setting the operating pressure
1.
In the setup mode, press the selection key until the corresponding sub-menu
is reached.
Ä
The filter icon blinks and “C" is shown.
2.
Press the input key for 3 seconds if you want to change the setting.
3.
Use the selection key to set the operating pressure (200 bar, 200 bar or
200/300 bar).
4.
Confirm the change using the input key.
Setting the operating hours
1.
In the setup mode, press the selection key until the corresponding sub-menu
is reached.
Ä
The filter icon blinks.
2.
Press the input key for 2 seconds if you want to change the setting.
Ä
The last position starts blinking.
3.
Use the selection key to set the last position as desired.
4.
Confirm the change using the input key.
Ä
The next position starts blinking.
5.
Set the next positions accordingly.
7 | Commissioning and operation OPERATING MANUAL
74/150
A_002_en
28.08.2019

Table of Contents