4.3
P0041
The upper lower limits are to prevent operation errors and machine damage. If the output
frequency upper limit is 50 Hz and the maximum output frequency is 60 Hz, the output
frequency will be limited to 50 Hz. If the output frequency lower limit is 10 Hz, and the min-
imum output frequency ZP0038 is set to 1.0 Hz, then any command frequency between
1.0 to 10 Hz will generate a 10 Hz output from the drive.
The maximum output frequency ZP0033 is regarded to 100 %.
This parameter must be equal to or less than the output frequency upper limit ZP0040.
Output frequency lower limit value = (ZP0033 ZP0041) / 100
Figure 8: V/f curve
P0041
Ausgangsfrequenz: untere Grenze 0.0 to 100.0 %
EE Output frequency: lower limit 0.0 %
STOP BM_u_OutFreqlowerLimit 10:1 -