Setting the limit positions
3. Deleting the limit positions
using the master transmitter
Press the programming button and
the STOP button until the drive clicks
twice after 10 seconds.
If the shading solution is situated
between the limit positions, both
limit positions are deleted in the
procedure. If the shading solution is
situated in one of the limit positions,
only this position will be deleted.
1. Programming the Extend
limit position with the master
transmitter
Run the shading solution to the
Extend limit position. Then press
the programming button and the
EXTEND button until the drive clicks
once.
PSF(+) drives
2. Programming the Retract
limit position with the master
transmitter
Retract limit position stop
Run the shading solution to-
wards the upper stop until the
drive stops automatically.
To Retract limit position point
Run the shading solution to the
desired Retract position. Then
press the programming button
and the RETRACT button until
the drive clicks once.
1x click
1x click
2x click