97
Sun protection
Drives
Short! Short! Short! Short!
Short! Short! Short! Press
and
hold!
2. Setting the Retract limit
position using the operator
control
To upper stop
Run the shading solution to-
wards the upper stop until the
drive stops automatically.
To upper point
Run the shading solution to the
upper limit position . Then move
the shading solution in the Extend
direction briefly twice, waiting for
1 second between movements,
then in the Retract direction
until the drive stops automatically
and clicks once after 3 seconds
.
1. Setting the Extend limit
position using the operator
control
At least one switch on the drive head
must be in the position.
To lower point
Run the shading solution to the lower
limit position . Now move the shad-
ing solution up briefly twice, waiting
for 1 second in between movements,
then back down until the drive
stops automatically and clicks once
after 3 seconds .
3. Deleting the limit posit
ions
using the operator control
Run the drive for 6 seconds in the
Retract or Extend direction.
Then run through steps
to
of the deletion sequence shown
opposite at one second intervals
until the drive clicks twice.
When using operator controls with
maintained operation mode, a STOP
command must be issued after
every short drive command.
Setting the limit positions using the operator control
1x click
1x click